Anodize Inputs
The following setup options are provided by the Anodize process:
Enable Sealing Operation
By default, the Seal operation is included in Anodize routings (see
Anodize Routing). With this setup option, users can override the default on a part-by-part basis. To exclude Sealing from the routing, set the option to
false.
Number of Components per Loadbar
By default, the number of components processes at one time is determined as described in
Number of Parts per Load Window. With this setup option, users can override the default, and specify the number explicitly.
Anodizing Routing Strategy
By default, if the Anodize machine load window capacity (see
Number of Parts per Load Window) exceeds the current batch size (specified in the Production Scenario tab of the Cost Guide), the cost mode nevertheless assumes that the window is fully loaded due to the inclusion of different parts (parts with different part numbers from the current part). In such a case, the per-part anodizing costs are the same as the per-part cost when the window is fully loaded with the current part only.
With this setup option, users can override this assumption and specify that the number of parts per load window is bounded above by the batch size.
Select one of the following options:
• Fill Machine: load window is assumed to be fully loaded (see
Number of Parts per Load Window).
• Run Specified Batch Size: number of parts per load window is bounded above by the batch size (specified in the Production Scenario tab of the Cost Guide).
Users can also specify the number of parts per load window with the setup option .
Time to load all the parts on to the loadbar
By default, the time to hang one load of parts on the loadbar is calculated based on the number of parts per loadbar and on values looked up by part weight in the lookup table
tblandlingTimes (see
Anodize Formulas). With this setup option, users can override the default and specify the load time per loadbar explicitly.
Specify Anodize Coating Thickness
By default, the thickness of the oxidized layer is specified in millimeters by the following cost model variables (depending on the type of anodizing in the current routing):
• anodizingCoatingThicknessTypeI (0.01016mm in starting point Digital Factories)
• anodizingCoatingThicknessTypeII (0.02032mm in starting point Digital Factories)
• anodizingCoatingThicknessTypeIII (0.04064mm in starting point Digital Factories)
See
Anodization Formulas. With this setup option, users can override the default on a part-by-part basis, and specify the thickness explicitly.
Current Applied for Anodizing Process
By default the anodizing current density (amps per sq ft) is specified by the machine property
Anodize Current. See
Anodization Formulas. With this setup option, users can override the default on a part-by-part basis and specify the current density explicitly.
Clean Time for Anodizing per Loadbar
By default, clean time per load bar is specified by the machine property
Clean Time (see
Pre-treatment Formulas). Users can override the default on a part-by-part basis with this setup option.
Etch Time for Anodizing per Loadbar
By default, etch time per load bar is specified by the machine property
Etch Time (see
Pre-treatment Formulas). Users can override the default on a part-by-part basis with this setup option.
Deoxidize Time for Anodizing per Loadbar
By default, deoxidize time per load bar is specified by the machine property
Deoxidize Time (see
Pre-treatment Formulas). Users can override the default on a part-by-part basis with this setup option.
Sealing Time for Anodizing per Loadbar
By default, clean time per load bar is specified by the machine property
Clean Time (see
Post-treatment Formulas). Users can override the default on a part-by-part basis with this setup option.
Drying Time for Anodizing per Loadbar
By default, dry time per load bar is specified by the machine property
Dry Time (see
Post-treatment Formulas). Users can override the default on a part-by-part basis with this setup option.